PRODUCTS & SERVICES
SandPro is driven by innovation
and market awareness
Control your SSV and CHOKE with improved safety, reliability, and performance of production well and flow control.
The mSmartWing control system enhances well safety,
increases operational efficiency, lowers maintenance
costs and maximizes production.
Manual, remote and automated operations
Implement condition-based monitoring and maintenance using valve status data communicated via SCADA, telemetry or downloaded from onboard memory
ELECTRONICALLY ASSISTED HYDRAULIC CONTROL
The mSmartWing is a revolutionary solution that combines well and flow control on a production flowline.
The mSmartWing integrates an EOH fail-close ESD valve
and an electric actuated adjustable choke simultaneously.
The solution integrates pressure sensors with high/low set points to provide surface well control. Utilizing the electric actuated adjustable choke allows the mSmartWing to
increase/decrease flow.
The mSmartWing comes with optional full 2-way telemetry
that allows remote visibility to the status of the valve and
choke as well as command control to open/close ESD and
adjust choke settings.
Safety, reliability, and user-friendly operations are the design principles of the mSmartWing solution.

KEY FEATURES
▘Monitors and regulates ESD actuator pressure
▘UL 508A Listed and NEMA 1, 3R, 4 and 12 Encloser
▘Reduce wellsite visits
▘Hydraulic fluid leak detection system
▘Partial stroke test
▘Full SCADA capability and 2-way telemetry ability
▘Optimize flow rates with prompt choke adjustments
Condition Based Monitoring
The mSmartWing controller’s ability to acquire and communicate precise data on even small changes in hydraulic pressure supports condition-based monitoring and maintenance in many ways:
PREDICTIVE VALVE MAINTENANCE
Predictive maintenance is enabled by early detection of small operational anomalies. Partial stroke testing allows diagnosis of potential valve failure
without
stopping production and
with zero emissions.
Maintenance is reduced
and easier to schedule,
and production delays
are minimized.

ACUATOR PRESSURE STABILIZATION
Pressure stabilization eliminates progressive valve
closure and associated wear with mSafe2 monitoring
and automatically compensating for temperatureinduced variations.
LINE BREAK DETECTION
Identifies gradual losses in pressure over time
preventing hydraulic releases. Deviation from the
pressure gradient prompts an mSafe2 programmable
alarm or valve closure.
SPECIFICATIONS
Base: 36x32 inches (91x81 cm)
Height: 69 inches (175 cm)
Weight: 400 lbs. (181 kg)
Hydraulic outlet pressure: 300 to 2,000 PSI (1 to 138 Bar)
Oil volume: 2 gallon (7.57 L)
Operating temperature: -40°F to 185°F (-40°C to 85°C)
Electric power required: 120VAC
Communications: Modbus RS485 protocall
Accuracy of measurement: +-1%
Response time: +-1%
Internal memory capacity: 6 months minute by minute via USB