Field-proven in Latin and North America, the mSafe² design integrates electronic control and an electro-hydraulic pump to ensure the safety and performance of hydraulically actuated safety valves used in emergency shutdown applications.
The mSafe ² controller’s ability to acquire and communicate precise data on even small changes in hydraulic pressure supports condition-based monitoring and maintenance in many ways:
Predictive Valve Maintenance
Predictive maintenance is enabled by early detection of small operational anomalies. Partial stroke testing allows diagnosis of potential valve failure without stopping production and with zero emissions. Maintenance is reduced and easier to schedule, and production delays are minimized.
Acuator Pressure Stabilization
Pressure stabilization eliminates progressive valve closure and associated wear with mSafe ² monitoring and automatically compensating for temperature-induced variations.
Line Break Detection
Identifies gradual losses in pressure over time preventing hydraulic releases. Deviation from the pressure gradient prompts an mSafe ² programmable alarm or valve closure.
Monitors and regulates ESD actuator pressures
UL 508A Listed and NEMA 1, 3R, 4 and 12 Encloser
Reduce wellsite visits
Hydraulic fluid leak detection system
Partial stroke test
Full SCADA capability and 2-way telemetry ability
Available in sizes 2 1⁄16" 5K to 3 1⁄16" 10K
Base: 36x32 inches (91x81 cm)
Height: 69 inches (175 cm)
Weight: 400 lbs. (181 kg)
Hydraulic outlet pressure: 300 to 2,000 PSI (1 to 138 Bar)
Oil volume: 2 gallon (7.57 L)
Operating temperature: -40°F to 185°F (-40°C to 85°C)
Electric power required: 120VAC
Communications: Modbus RS485 protocall
Accuracy of measurement: .+-1%
Response time: .+-1%
Internal memory capacity: 6 months minute by minute via USB
24-hour Dispatch Number
+1 701-453-3443
careers@sandpro.com
Monday-Friday
7:00 am - 5:00 pm
© 2022 SandPro LLC. All Rights Reserved. Privacy Policy.
Terms of Use • Privacy Policy