PRODUCTS & SERVICES

SandPro is driven by innovation
and market awareness

SAND MANAGEMENT


mSAND - AUTOMATED BLOW DOWN SYSTEM

The mSand system is designed to reduce wellsite exposure and increase efficiencies during blow down operations.

ALL-IN-ONE BLOW DOWN SYSTEM

Electro-hydraulic mSand panel

PV 1/2: 2" or 3" Pressure Transducers Class 1 Div. 1

PV 1/2: 2" or 3" Plug/ball valves hydraulic actuated with position switches (Standard)

CV-3 (CPO ON/OFF): Calibrated orifice ON/OFF choke, hydraulic actuated with position switches (included in the basic equipment)

DESCRIPTION OF OPERATION MODES:

AUTONOMOUS

High Inlet Pressure (PT3)

Differential Pressure (PT3-PT2)

Time Between Dumps

Dump Holding Period

Valve Seat Test (PV1/PV2)

MANUAL

Manual locally from the panel:

Double-button operation sequence

REMOTE

Operation through SCADA

(ModBus Protocol/Telemetry)

FAILSAFE

In the event of detection of a non-system fault, mSand will send a shutdown signal for well closing

Environmental-Social-Governance

  • CUSTOMER ADVANTAGES
  • KEY FEATURES
  • TECHNICAL SPECIFICATIONS

Reduced personnel exposure

Reduced OPEX by fewer well visits

Reduced maintenance costs by protecting the integrity of the valves

Easy installation, predictive operation with low operator training times

Traceability of the entire operation through internal data storage

Customized dump valve to minimize wear and reduce replacement costs

Environmental-Social-Governance

Manual, remote and automated operations

Suitable for temporary or permanent applications

Sequential operation of opening/closing of complete system

Sensor monitored dual isolation leak detection

Compatible with SSV/ESD valve solutions

UL 508A listed and NEMA 1, 3R, 4 and 12 encloser

Communication: SCADA (ModBus Protocol) and 2-way telemetry

Available in standard or NACE service

mSAND SYSTEM
SPECIFICATIONS

Hydraulic outlet pressure: 2.000 PSI

Oil Volume: 2 gallon (7.57 L)

Electric Power Required: 120VAC

Temperature: -40°F to 185°F (-40°C to 85°C)

Communications: Modbus RS485 protocall